SET_TS_VALUNIT
About the function
This function is used to change the unit of a time series. Especially calculated series may contain several multiplied time series and result in different unit than the input time series.
Syntax
- SET_TS_VALUNIT(t,d)
- SET_TS_VALUNIT(t,s)
Description
# | Type | Description |
---|---|---|
1 | t | Time series. |
2 | d or s | Unit code number or text. |
See Unit codes for SET_TS_VALUNIT. Note! The text for unit code is language dependent. If in doubt, open the Time series application search window. Look in the Unit drop down menu to check if you are using the correct language for the code.
Example
Example 1: @SET_TS_VALUNIT(t,d)
To change the unit of a result series to meters/second, the unit code is 120:
@SET_TS_VALUNIT(timeseries1,120)
Example 2: @SET_TS_VALUNIT(t,s)
To change the unit of a result series to meters/second using text:
@SET_TS_VALUNIT(timeseries1,'m/sec')
This gives the same result as example 1.