CorrectCopyValue
About the function
Corrects errors on a previously validated time series using a copy of the previous value. Values with correction using copy value are set to corrected and marked with C02, meaning correction method 2. You can see this code if you turn on value information in Nimbus.
Syntax
- CorrectCopyValue(t,d,s)
Description
# | Type | Description |
---|---|---|
1 | t | Time series to be corrected. |
2 | d | Value describing the maximum number of allowed copies. |
3 | s | Symbol describing whether or not corrected values can be used. This is specified as either 'TRUE' or 'FALSE'. |
Example
Waterlevel_hour_VEE = @CorrectCopyValue(@ValidateAbsLimit(@t('Waterlevel_hour_raw'),207,210),3,'TRUE')
This example validates the time series using absolute limits. Any errors found are replaced by a copy of the previous value. Maximum values that can be copied are set to 3 and corrected values can be used.